DSpace logo
Please use this identifier to cite or link to this item: http://172.20.40.131:8080/jspui/handle/123456789/3546
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVasava, Smita Natvarbhai-
dc.contributor.authorSadaria, Roshni Gokaldas-
dc.date.accessioned2021-10-20T13:57:15Z-
dc.date.available2021-10-20T13:57:15Z-
dc.date.issued2020-12-
dc.identifier.issn2249-782X-
dc.identifier.urihttp://172.20.40.131:80/jspui/handle/123456789/3546-
dc.description.abstractIntroduction: Now-a-days quality is the key aspect of clinical laboratory services. The six sigma metrics is an important quality measurement method for evaluating the performance of the clinical laboratory. Aim: To assess the analytical performance of clinical biochemistry laboratory by utilising thyroid profile and cortisol parameters from Internal Quality Control (IQC) data and to calculate sigma values. Materials and Methods: Study was conducted at Clinical Biochemistry Laboratory, Dhiraj General Hospital, Piparia, Gujarat, India. Retrospectively, IQC data of thyroid profile and cortisol were utilised for six subsequent months (July to December 2019). Coefficient of Variation (CV%) and bias were calculated from IQC data, from that the sigma values were calculated. The sigma values <3, >3 and >6 were indicated by poor performance procedure, good performance and world class performance, respectively. Results: The sigma values were estimated by calculating mean of six months. The mean sigma value of Thyroid Stimulating Hormone (TSH) and Cortisol were >3 for six months which indicated the good performance. However, sigma value of Triiodothyronine (T3), Tetraiodothyronine (T4) were found to be <3 which indicated poor performance. Conclusion: Six sigma methodology applications for thyroid profile and cortisol was evaluated, it was generally found as good. While T3 and T4 parameters showed low sigma values which requires detailed root cause analysis of analytical process. With the help of six sigma methodology, in clinical biochemistry laboratories, an appropriate Quality Control (QC) programming should be done for each parameter. To maintain six sigma levels is challenging to quality management personnel of laboratory, but it will be helpful to improve quality level in the clinical laboratories.en_US
dc.language.isoen_USen_US
dc.publisherJournal of Clinical and Diagnostic Researchen_US
dc.subjectInternal Quality Controlen_US
dc.subjectSerum Cortisolen_US
dc.subjectSix Sigmaen_US
dc.subjectThyroid Function Testsen_US
dc.titleApplication of Sigma Metrics for Evaluating the Analytical Performance of Thyroid Profile and Cortisol in Clinical Biochemistry Laboratoryen_US
dc.typeArticleen_US
Appears in Collections:Faculty Publications

Files in This Item:
File Description SizeFormat 
47345_CE[Ra]_F(Sh)_PF1(AG_SHU)_PFA(SHU)_PB(AG_SHU)_PN(SL).pdf125.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.